<LOGO>
FM Transmitter Measurement Report
Created: 2024-10-22 12-33-03
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 71 dBuV YLEX
Pilot RDS Phase Difference
7.5 kHz 2.3 kHz 51 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 64 kHz 19059 0,8552
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-0,1 dBr 2,87 dBr 5,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 2 (Affairs) 0 1 1 1 12:33, 22.10.2024
RT
"YleX Etusivu: Sikke "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6205, 6201, 6203, 6207
FM Scope Max at: 64 kHz MIN: 9 kHz % above 76 kHz: 0,8552 Acquired: 2024/10/22 12.31.59 Total samples: 19059 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 5,0 dBr MIN: -0,1 dBr AVE: 2,87 dBr % above 12,2 dBr: 0,0 Last value: 1,4 dBr (2024/10/22 12.31.59) 12.18 12.20 12.22 12.24 12.26 12.28 12.30 0 50 100 Dev. MAX [kHz] 0 2 4 6 Pm [dBr]